I need a KMO-certified technician to install a used Daikin Perfera (FTXM50R / RXM50R) in my studio at Refshaleøen.Technical Setup:Logistics: The outdoor unit will already be positioned on the roof directly above the indoor unit.Vertical Run: You need to drill a vertical hole through the ceiling/roof for the lines. Professional weatherproofing/sealing of the roof penetration is required.Drainage: There is a surface-mounted drain pipe running from the roof to the floor right next to the indoor unit. You can tap the AC drain directly into this pipe.Access: I have scaffolding and ladders on-site for the 4m ceiling height.Studio Needs: Heavy-duty vibration dampers for the roof mount are essential to prevent structural noise.Materials: Please include copper pipes, cabling, roof sealing materials, and dampers in your bid.
Is the installation for a new location or a replacement of an existing unit?: New location
Is the Daikin AC unit already purchased and available on site?: No
What is the model number of the Daikin AC unit?: FTXM50R2V1B / RXM50R2V1B
Is the installation indoors or outdoors?: Indoors
Does the installation require mounting on a wall, ceiling, or floor?: Wall
Is there existing electrical wiring compatible with the AC unit?: Yes
Do you need assistance with electrical work, like installing power outlets or circuit breakers?: Not Sure
Is any ductwork required for the installation?: No
Do you need removal and disposal of an old AC unit?: No
Will you provide the Daikin AC unit for installation or should the technician arrange the purchase?: I will provide the unit
Are the copper pipes, cabling, and other materials already available or should the technician supply all materials?: Technician must supply all materials
Is the vertical hole for the lines drilling allowed without special permissions from building management?: Yes, permission is granted
Is there a preferred method or material for weatherproofing and sealing the roof penetration?: No, leave it to technician's discretion
Are the heavy-duty vibration dampers already selected or should the technician recommend and supply appropriate ones?: Technician should supply recommendations
Should the technician install any additional mounting brackets or supports for the indoor unit on the wall?: No, mounting points are already prepared
Will the technician be responsible for testing the AC unit's functionality after installation?: Yes, full functional testing required
Is there a preference for when the installation should be cleaned up and how waste materials should be handled?: I will handle cleanup separately
Do you require the technician to install the electrical connections (power outlets, breakers) for the AC unit?: Ved ikke
Please specify the exact location on the wall where the indoor unit should be mounted (height or distance from reference points).: Just above the Window
Are there any weight restrictions or structural limitations on the roof for mounting the outdoor unit with vibration dampers?: No